Dräger Babylog® VN600

​Babylog® VN600 comes with a new user interface and design which makes operation easier and more efficient. The neonatal ventilator supports lung and brain protective ventilation modes throughout the whole respiratory cycle and can be easily integrated in a developmental care friendly workplace.

Operation principle and user interface

The brilliant user interface combined with a timely glass touch technology supports intuitive operation and lowers education times and possible errors.

  • Quick and safe to operate even in the most stressful situations due to intuitive menu access to both settings and your clinical data.
  • All patient data, alarms and trends are fully recorded. Conveniently exported via USB interface.
  • Switch between multiple view configurations with the touch of a finger.
  • Step-by-step guidance leads you through every procedure.
  • Easy to read and navigate thanks to our new colour concept and glass touch display.
  • The 360° alarm light flashes in the color of the corresponding alarm priority and is visible from every direction.

Lung and brain protective ventilation

Dräger Babylog ventilators safeguarding high flow O2 therapy

  • Safeguarding
    Dräger O2 therapy allows the caregiver to sageguard pressures at the patient's interface by setting a maximum pressure to protect the immature lungs from undesired high airway pressures. A display of the measured pressure at the interfaces supports an easy setting for the user.

  • For all patients
    Support of high flow O2 therapy with HFNC with Dräger O2 therapy up to 30 L/min for paediatric patients and up to 15 L/min for neonates. With Optiflow Junior 2* a broad range of patients can find a comfortable interface.

  • Seamless application
    With the Babylog family one breathing circuit system can be used for all therapy types. This allows for a quick and safe transition between non-invasive ventilation and high flow O2 therapy with HFNC. Less material usage and difference in systems may safe time and reduces costs and disposal.

  • Seamless transition
    By using Dräger ventilators you can conveniently switch your patient between traditional invasive ventilation, non-invasive ventilatory support, or high flow O2 therapy with HFNC to meet changing needs while still using the same device.

Non-invasive ventilation (NIV)

  • Reliable pressure control and monitoring
  • Demand flow principle to correct for leakages (in slope operation), thus stable pressure even in presence of leakages
  • Trend data over the whole ventilation therapy
  • Ventilation with only one breathing circuit possible, that allows for kangaroo care
  • BabyFlow® plus accessories for non-invasive respiratory support are available in different sizes providing comfort and optimum CPAP support to the infant.

Connectivity

We envision a future of acute care where medical devices are connected as a system. Interoperability between different devices can help to avoid preventable medical errors and potentially serious inefficiencies. The new standardised network protocol named SDC makes the safe and dynamic connectivity in the hospital possible which will allow interoperability of medical devices in the future.

Our first step will be connectivity through CC300:

  • Full HL7 data export to HIS from all devices: reliability exchange high-quality data in a standardised format between medical devices and EMR.
  • Future-proof open connectivity: standardised and secure communication between medical devices with a high level of cyber security.

Comprehensive Services

​Our comprehensive consulting and support services ensure maximum performance in more fields than you would expect.

  • Product service such as inspection and device maintenance to ensure a maximum uptime
  • Professional service like IT consulting and system integration
  • Online and class-room trainings
  • Multivendor service
  • Digital services like network-based services and analysis of device data
  • Access to online neonatal community BabyFirst community for clinicians and parents of premature babies. Visit www.babyfirst.com.

Downloads

Accessory Catalogue 2024, en
Accessory Catalogue 2024, en

Always an essential part of your acute care

Download

Did you know? (APRV), en
Did you know? (APRV), en

Download

Did you know? (APRV), en
Did you know? (APRV), en

Download

Did you know? (C20/C), en
Did you know? (MMV), en
Did you know? (PPS), en
Did you know? (Pressure Link), en
Did you know? (Trigger), en
Did you know? (Trigger), en
IfU Transport Supply Unit NO 9052134
IFU Babylog VN800 / VN600 - SW 2.n - 9511662 no
IFU Babylog VN800 / VN600 9055655 no
IFU Bed Coupling 9052621 ME
IFU SP Evita V series / Babylog VN series / Batteries 9510324 en, bg me
IFU SP Low trolley - 9512139 de-me
REIN Reprocessing instructions Evita V series / Babylog VN series 9510385 no

Technical Data

Protective Ventilation

Operational Application
Fully-featured, high-end NICU ventilator
Patient categories
Pediatric patients, Neonates
Add Ons
Includes a set of treatment tools to apply individual, lung protective ventilation strategies
Inspiratory Flow
max. 120 L/min

Ventilation Modes

Pressure controlled ventilation
Support of spontaneous breathing

Technical Data

Screen Display
15.6 inches Capacitive glass touchscreen
Serial interfaces
RS232, USB, LAN
Internal Battery
30 min
External Battery
Fault-Cause-Remedy

Features

Smart Pulmonary View
Volume Guarantee
Non-invasive ventilation
CO2-Monitoring
ATC
O2-therapy
Loops
Trends

Compare with related Products

Get in touch with Dräger

Man with blue shirt

Dräger Norge AS

​Innspurten​ ​9,​ ​0663​ ​Oslo

+47 23 65 38 00

​Åpningstider:
Mandag-Fredag​ ​kl.​ ​08:00-16:00