Zeus® Infinity® Empowered Anestesimaskiner

Zeus® Infinity® Empowered

Contact us

Zeus® Infinity® Empowered

Lung-protective ventilation functionalities, cost-saving gas delivery technology, decision-support tools and comprehensive monitoring. Zeus IE integrates them all into one advanced anaesthesia workstation. It can, hence, improve clinical outcome, workflow efficiency, and cost savings throughout the anesthesia process.

360 Product View

Draeger Zeus Infinity Empowered 360

Downloads

Zeus IE Product Information, en
Zeus IE Product Information, en

Download

Smart Ventilation Control (SVC) Brochure, en
Smart Ventilation Control (SVC) Brochure, en

Download

Zeus IE SW 2.0 Overview Brochure, en-gb
Zeus IE SW 2.0 Overview Brochure, en-gb

Download

Improving Outcome with Zeus IE “Smart Ventilation Control (SVC)”, Reference Case Salzkotten, Germany, en
Low Flow Anaesthesia Booklet, en
Zeus IE Brochure, en
Zeus IE Smart Ventilation Control Video, en
IfU AGS 9038579 me
IFU SilverLine - 9037337 de-me
IFU Smart Ventilation Control - Zeus IE - SW2.n 9056171 no
IFU SP Connections on the gas supply block - 9513626 de-me
IFU SP Zeus IE SW 2.n - Hygiene 9510460 no
IFU Zeus IE SW2.n 9510809 no
Smarter Anaesthesia Dosing Infographic, en

Technical Data

Lung Protective Ventilation

Operational Application
State-of-the-art integrated anesthesia solution
Patient categories
Adults, pediatrics, neonates
Fresh gas decoupling
Ventilator technology
Blower-Technology, Electronically-controlled TurboVent2
APL-Technology / Precise manual ventilaton
Dräger APL-Valve
Breathing gas warmer
Not necessary
Low- and minimal flow setting support
Uptake-oriented anaesthetic guidance (closed system)

Ventilation Modes

Man/Spon
CPAP in Man/Spon
Volume Controlled (VC)
VC Synchronized + PS
Pressure Controlled (PC)
PC Synchronized + PS
Pressure Support
Volume Controlled AutoFlow
APRV

Features

Screen Display
20" touch-screen with storable view and profiles
Vaporizers capability
Up to 2 DIVA modules for direct injection of volatile anaesthetic agents
Device self test
Programmable time controlled automatic self test
LOOPS (p/V-loop and flow/V-loop)
Yes
Smart Pilot View
Integrated (optional)
Patient gas module
in/ex O2, N2O, CO2, Agent

Technical Data

Device versions
Trolley version, ceiling version
Breathing system
+ closed; integrated; anaesthetic gas monitoring. Closed-loop mode
Fresh-gas mixer
electronic mixer (by setting values)
Gases
O2, Air, N2O
RFID Technology
Serial interfaces
3x ethernet, 3x RS232

Safety Concept

Emergency ventilation in case of total gas supply failure
Typical battery run-time in case of power supply failure
up to 90 min
Emergency start-up procedure
✗ (only oxygen can be doesed)

Compare with related Products

Get in touch with Dräger

Man with blue shirt

Dräger Norge AS

​Innspurten​ ​9,​ ​0663​ ​Oslo

+47 23 65 38 00

​Åpningstider:
Mandag-Fredag​ ​kl.​ ​08:00-16:00