Zeus® Infinity® Empowered Anestesimaskiner

Zeus® Infinity® Empowered

Contact us

Zeus® Infinity® Empowered

Lung-protective ventilation functionalities, cost-saving gas delivery technology, decision-support tools and comprehensive monitoring. Zeus IE integrates them all into one advanced anaesthesia workstation. It can, hence, improve clinical outcome, workflow efficiency, and cost savings throughout the anesthesia process.

360 Product View

Draeger Zeus Infinity Empowered 360

Downloads

Zeus IE Product Information, en
Zeus IE Product Information, en

Download

Zeus IE Brochure, en
Zeus IE Brochure, en

Outstanding results begin with a perfect process. Process orientation is a key factor in providing the kind of care your patients expect and our people want to deliver. This kind of integration will take your workflow to the next level. It's a real revolution.

Download

Zeus IE Smart Ventilation Control Video, en
Zeus IE Smart Ventilation Control Video, en

Download

Zeus IE SW 2.0 Overview Brochure, en-gb
Low Flow Anaesthesia Booklet, en
IFU Smart Ventilation Control - Zeus IE - SW2.n 9056171 no
IFU SP Zeus IE SW 2.n - Hygiene 9510460 no
IFU Zeus IE SW2.n 9510809 no
Smarter Anaesthesia Dosing Infographic, en

Technical Data

Lung Protective Ventilation

Operational Application
State-of-the-art integrated anesthesia solution
Patient categories
Adults, pediatrics, neonates
Fresh gas decoupling
Ventilator technology
Blower-Technology, Electronically-controlled TurboVent2
APL-Technology / Precise manual ventilaton
Dräger APL-Valve
Breathing gas warmer
Not necessary
Low- and minimal flow setting support
Uptake-oriented anaesthetic guidance (closed system)

Ventilation Modes

Man/Spon
CPAP in Man/Spon
Volume Controlled (VC)
VC Synchronized + PS
Pressure Controlled (PC)
PC Synchronized + PS
Pressure Support
Volume Controlled AutoFlow
APRV

Features

Screen Display
20" touch-screen with storable view and profiles
Vaporizers capability
Up to 2 DIVA modules for direct injection of volatile anaesthetic agents
Device self test
Programmable time controlled automatic self test
LOOPS (p/V-loop and flow/V-loop)
Yes
Smart Pilot View
Integrated (optional)
Patient gas module
in/ex O2, N2O, CO2, Agent

Technical Data

Device versions
Trolley version, ceiling version
Breathing system
+ closed; integrated; anaesthetic gas monitoring. Closed-loop mode
Fresh-gas mixer
electronic mixer (by setting values)
Gases
O2, Air, N2O
RFID Technology
Serial interfaces
3x ethernet, 3x RS232

Safety Concept

Emergency ventilation in case of total gas supply failure
Typical battery run-time in case of power supply failure
up to 90 min
Emergency start-up procedure
✗ (only oxygen can be doesed)