Light and robust SCBA provides dependable breathing protection.
Quick Links
SpecificationsAccessoriesDownloadsContact us
Fire Fighting
Application
2,7 Kg
Weight (backplate & harness)
0 - 300 bar
Input Pressure
Open full specifications
Highlights
The Dräger PSS 3000 is a high performing breathing apparatus for firefighters. Combining comfort with exceptional pneumatic performance, it is designed for applications where simplicity and ease of use are key essentials. Lightweight yet robust, and easy to don, this advanced breathing apparatus provides depedable breathing protection.
Light, robust and simple to use
Dräger PSS 3000 is one of the lightest self contained breathing apparatus carrying system available. We have applied the same advanced technology and design philosophy which was derived from our class leading range of short and extended duration prof … More informationessional breathing apparatus. The extremely durable carrying system features our ultra lightweight, high strength carbon composite carrying frame which exhibits outstanding thermal, impact and chemical resistance properties. Suitable for use in all conditions easy and quick to don, the lightweight harness has been specially designed to retain its form over a wide range of environmental temperatures and conditions. Utilizing materials which have good chemical and abrasion resistance and also meet the heat and flame requirements of EN137:2006 (Type 2).
Proven air supply technology
Versatility is the foundation of the Dräger PSS series of products. The breathing apparatus PSS 3000 enables the wearer to benefit from leading edge breathing protection technology incorporating, the same advanced pneumatic system used in our class l … More informationeading breathing apparatus.
Easy to maintain and service
Quick and uncomplicated to service, the breathing apparatus PSS 3000 incorporates a number of unique design features to ensure that downtime, and therefore costs, are kept to a minimum during maintenance. All the major components are simple and quick … More information to remove and re-assemble. The harness is attached to the carrying frame by a single-piece retention method. In addition the first stage pressure reducer, integrated into the carrying frame for added protection, can be readily removed. Options for every eventuality: Choice of lung demand valves Full FPS 7000 facemask configuration options Utilizing the proven PSS 7000 pressure reducer Electronic voice communications Dräger compressed air breathing cylinders Secondary supply hose connections for rescue and decontamination Available with Pneumatic gauge or electronic TX gauge and integrated PASS (Bodyguard 1500) High performing, easy to use and with proven technology, the Dräger PSS 3000 guarantees a lifetime of depenable service whilst at the same time minimizing the costs of ownership.
Enhanced carrying system
By utilising the state-of-the-art pressure mapping technology, we have developed a carrying system which follows the natural contours of the body and therefore provides improved stability and reduced back strain, stress and fatigue. The contoured car … More informationrying harness provides maximum comfort at both the shoulders and the waist, but optimizes load distribution comfortably and securely, in line with the body’s centre of gravity. Despite this emphasis on wearing comfort, you can rest assured that we have not compromised on the choice of the most rugged and durable materials available, in order to minimize the impact of the most hostile of environments.
Integrated hoses
Both the medium pressure air supply and gauge hoses are integrated into the carrying-frame to reduce the risk of snagging and entanglement, which results in improved security and safety whilst entering and working in confined spaces. With the ability … More information to re-route these hoses from one side to the other in order to suit customer preferences for gauge access, this design feature also facilitates the easy replacement of each hose.
Specifications
Fire Fighting
Application
2,7 Kg
Weight (backplate & harness)
0 - 300 bar
Input Pressure
Key Facts
Application
Fire Fighting
Pivoting waist Belt
no
Sliding Waist Belt
no
Height Adjustment
no
Reflective Straps
no
Buddy lights
no
Monitoring System
Mechanical gauge
yes
Mechanical gauge with
transmitting function
no
Digital gauge
no
Automatically activated PASS
no
Head Up Display (HUD)
no
Compatible with Dräger FireGround
no
FPS IMD
no
Technical Data
Weight (backplate & harness)
2,7 Kg
Input Pressure
0 - 300 bar
Lung Demand Valves
Lung Demand Valves
yes
Compressed Air Cylinders
One Cylinder Configuration
yes
Two Cylinder Configuration
no
Twinpack Configuration
no
Full Face Masks
FPS 7000
yes
Panorama Nova
yes
Communication systems
FPS-5000-COM
yes
FPS-7000-COM
yes
FPS-Com Voice
yes
Complementary products
PSS Safety Belt
no
QuickConnect
no
Additional medium pressure (rescue) hoses
yes optional
Charge-Air connection
yes optional
Approvals
EN 137:2006 (Type 2)
yes
GOST
no
Aus/NZ
yes
NIOSH
yes
NFPA
no
EN 14593 Part 1
yes
SOLAS II-2
yes
MED
yes
See the whole Product System.
—
This product is part of a Dräger system solution. Combine it with the following system components.
- Professional self-contained breathing apparatus for firefighting- Offers comfort, stability, lightweight and advanced harness materials for extended wear
Offers comfort, stability, lightweight and advanced harness materials for extended wear
Tests full-face masks, chemical protection suits, and compressed air breathing apparatus (others possible, if required) for functionality and leak tightness"
Versatile LDV holder can be positioned on the Dräger PSS® and Dräger PAS® series to suit the requirements of the user, incorporating a simple to use secure connector, designed around the LDV.
Secondary supply hose
The Dräger PSS AirBoss can be equipped with a range of secondary supply hoses for shoulder or waist mounting. Allowing firefighters to connect to airlines, supply breathing air to each other and victims.
Downloads
—
Download product information, instructions for use and other important files.