Dräger X-zone 5800

State-of-the-art area monitoring – the Dräger X-zone 5800 in combination with the Dräger X-am 5000, 5100 or 5600 gas detection instruments can be used for the measurement of up to six gases. The internal pump and continuous power supply in the explosive area of zone 0 extend the range of applications in mobile gas detection technology.

Area monitor

  • combination with Dräger X-am 5000, 5100 or 5600 – measurement of up to 6 gases
  • extensive area monitoring thanks to fenceline of up to 25 devices
  • option for permanent power supply in explosive areas (zone 0) 

Innovative area monitoring

The Dräger X-zone 5800 transforms the Dräger personal gas detection instruments X-am 5000, 5100 and 5600 into innovative area monitoring devices for a wide range of applications. A patented combination for increased safety – in addition to the personal air monitors carried on the body, these area monitors are positioned where gas hazards are expected.

Extended area monitoring

The  explosion-protected gateway Dräger ConHub transmits measured values and alarms from the Dräger X-zone 5x00 area monitor via a Modbus cable as well as data from up to 20 Dräger X-am 2800/5800 and Pac devices with Bluetooth® function to the Dräger Gas Detection Connect cloud solution. This gives you deeper insight into areas at risk while ensuring more efficient use of your fleet and increased safety of your facility.

Clear warning

Even from a distance, the illuminated green LED ring indicates that the air is free of toxic and combustible gases. Upon detection of gas hazards, the LED color changes from green to red, thus providing a clear visual warning that gas is present. Additionally, a loud and highly audible evacuation alarm is emitted. The Dräger X-zone 5800 gas entry location permits gas to diffuse into the Dräger X-am 5000, 5100 or 5600 from all sides.

Wireless fenceline

Up to 25 Dräger X-zone 5800 can be automatically interconnected to form a wireless fenceline. The interconnection of the area monitoring devices allows for rapid establishment of safety networks for larger areas.

A Dräger X-zone 5800 detecting a gas alarm transmits the alarm signal to all interconnected units. A red flashing master alarm in the unit detecting the gas contrasts with red/green flashing alarms of the connected units. This provides simple recognition of alarm status and the actual location of the hazard.

With the corresponding configuration, the maximum gas concentration in the monitored area is shown on the display. Combined with the display of the X-zone ID a clear containment of the hazard area is possible.

Continuous operation for up to 120 hours

The 24 Ah battery of the Dräger X-zone 5800 provides up to 120 hours of continuous operation – up to a complete working week.

The Power Supply Ex is available for continuous use of the X-zone 5800. It offers a 50 m supply from a safe area to a potentially explosive area and is even approved for use with the X-zone 5800 in Zone 0.

For safe transport, the cable of the Power Supply Ex is rolled up on a cable drum in which the power supply is also integrated.

Pump or diffusion mode – suitable for your respective application

The X-zone 5800 offers you both the possibility to draw in gas from a distance of up to 30 m in pump mode and the use in diffusion mode. The switch between these two options takes less than a minute. Simply exchange the pump cover or the supplied diffusion cover against each other. The X-zone 5800 is ready for another measuring operation – without any tools.

Other benefits

  • 360°-gas entry
  • Approval for Ex-Zone 0
  • individually configurable with the Dräger CC-Vision PC software (e.g. alarm frequency)
  • inductive charging station: easy and convenient non-contact charging (outside the Ex-area)

Interfaces

The interfaces on the back of the device offer the possibility of switching actuators in case of alarms by means of the configurable relay. The interface can also directly forward device data, such as measured values of sensors and alarms, via Modbus protocol. This allows you to integrate the devices into existing evaluation units.

Downloads

X zone 5800 Product Information, en
X zone 5800 Product Information, en

State-of-the-art area monitoring – the Dräger X-zone 5800 in combination with the Dräger X-am 5000, 5100 or 5600 gas detection instruments can be used for the measurement of up to six gases. The internal pump and continuous power supply in the explosive area of zone 0 extend the range of applications in mobile gas detection technology.

Download

CC-Vision Basic 8.1.4
CC-Vision Basic 8.1.4

Release Date: 29th October, 2024

Download

Portable Gas Detection Portfolio brochure, en
Portable Gas Detection Portfolio brochure, en

Download

Brochure: Dräger sampling hoses for portable gas detectors
CC-Vision Software History, en
Declaration of Conformity X-zone 5x00 Battery
IFU SP X-zone 5500/5800 - Notes on approval - 9033499 en
IFU X-zone 5500 / 5800 - 9033112 de-me
IFU X-zone 5500 / 5800 - 9033182 pt-me

Get in touch with Dräger

Smiling woman with blonde hair

Dräger Sverige AB - Säkerhet

Gamlestadsvägen​ ​18C
41502​ ​Göteborg

+46 10 344 40 00