PhosgeneCOCl2
Details
CAS-No.: | 75-44-5 |
---|---|
UN-No.: | 1076 |
EINECS No.: | 200-870-3 |
Kemler Code: | 268 |
Warning sign
- 268
- 1076
Hazard signs
Occupational exposure limit
- TWA (ppm) 0.02
- STEL (ppm) 0.06
- TWA (mg/m3) 0.08
- STEL (mg/m3) 0.25
- H: 280
Contains gas under pressure; may explode if heated - H: 314
Causes severe skin burns
and eye damage. - H: 330
Fatal if inhaled.
- P: 260
Do not breathe dust/fume/gas/mist/vapours/spray - P: 301 + 312 + 330
Wear protective gloves/protective
clothing/eye protection/
face protection. - P: 303 + 361 + 353
IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower. - P: 304 + 340
IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. - P: 315
Get immediate medical advice/attention - P: 403
Store in a well-ventilated place - P: 405
Store locked up
- EUH: 071
Corrosive to the respiratory tract
目前沒有 GHS 分類。
Melting point: | |
---|---|
Boiling Point: | |
Density (at 20 °C): | 0,004531 (0°C) g/cm3 |
Ionization: | ~11.2 eV |
Vapor Pressure (at 20 °C): | 1586 hPa |
Details
0 | No explosion danger | |
1 | Instable when heated | |
Water suitable as an extinguishing agent | ||
4 | Extremely dangerous | |
DG-EA: | 2XE |
Also known as:
- Carbon oxychloride
- Carbonyl chloride
- Carbonyl dichloride
- Chloroformyl chloride
- Chloroformylchlorid
- Phosgene
Suitable products for Phosgene COCl2
Whether portable gas detectors, tubes or personal protective equipment - Dräger offers a comprehensive portfolio to protect you when handling hazardous substances.
Get in touch with Dräger
If you need further advice for the product selection or if you have not yet found what you want, get in touch with us, we'll find a solution for you.
Discover more: Dräger VOICE - The hazmat-based safety product finder
You know what - We know how! Our database provides you with basic information on more than 1,500 hazardous substances and guide you to the suitable safety equipment. Give it a try!